TYPICAL MALFUNCTION THRESHOLDS
P0751
Detection criteria
[OFF malfunction]
Both of the following conditions are met: OFF malfunction (A) and (B)
2 detections are necessary per driving cycle:
1st detection; temporary flag ON
2nd detection; pending fault code ON
OFF malfunction (A)
Input speed/Output speed
OFF malfunction (B)
Input speed/Output speed
[ON malfunction]
Both of the following conditions are met: ON malfunction (A) and (B)
ON malfunction (A)
Input speed/Output speed
ON malfunction (B)
NE current − NE last
P0756
Detection criteria
[OFF malfunction]
All of the following conditions are met: OFF malfunction (A), (B) and (C)
2 detections are necessary per driving cycle:
1st detection; temporary flag ON
2nd detection; pending fault code ON
OFF malfunction (A)
Input speed/Output speed
OFF malfunction (B)
Input speed/Output speed
OFF malfunction (C)
Input speed/Output speed
[ON malfunction]
All of the following conditions are met: ON malfunction (A), (B) and (C)
ON malfunction (A)
Input speed/Output speed
ON malfunction (B)
Input speed/Output speed
ON malfunction (C)
Input speed/Output speed
2005 CELICA (RM1131U)
DIAGNOSTICS
−
AUTOMATIC TRANSAXLE (U341E)
1015
Threshold
0.64 to 0.78
Change as follows
0.95 to 1.09 (Last)
↓
0.64 to 0.78 (Current)
Not changed as follows
0.95 to 1.09 (Last)
↓
0.64 to 0.78 (Current)
1,100 rpm or more
Threshold
1.50 to 1.80
0.95 to 1.09
0.95 to 1.09
2.75 to 3.35
0.64 to 0.78
0.64 to 0.78
DI−815