MONITOR STRATEGY
Related DTCs
Required sensors/Components
Frequency of operation
Duration
MIL operation
Sequence of operation
TYPICAL ENABLING CONDITIONS
Item
The monitor will run whenever these
DTCs are not present.
Range check (Fluttering, Low resistance)
The typical enabling condition is not avail-
able.
Range check (High resistance)
Time after engine start
TYPICAL MALFUNCTION THRESHOLDS
Detection criteria
Range check (Fluttering)
TFT (transmission fluid temperature) sensor resistance
Range check (Low resistance)
TFT sensor resistance
Range check (High resistance)
TFT sensor resistance
COMPONENT OPERATING RANGE
Parameter
TFT sensor
2005 CELICA (RM1131U)
DIAGNOSTICS
P0710
P0712
P0713
ATF temperature sensor (TFT sensor)
Continuous
0.5 sec.
Immediate
None
Minimum
15 min. or more
AUTOMATIC TRANSAXLE (U240E)
ATF temperature sensor/Range check (Fluttering)
ATF temperature sensor/Range check (Low resistance)
ATF temperature sensor/Range check (High resistance)
Specification
See page DI−669
Less than 79 Ω
More than 156 kΩ
Less than 79 Ω
More than 156 kΩ
Standard value
Atmospheric temperature to approx. 130°C (266°F)
907
Maximum
Threshold
or
DI−707

Hide quick links: