TERMINALS OF ECM
E10
Each ECM terminals standard normal voltage is shown in the table below. In the table, first follow the informa-
tion under "Condition".
Look under "Symbols (Terminals No.)" for the terminals to be inspected.
The standard normal voltage between the terminals is shown under "STD Voltage".
Use the illustration above as a reference for the ECM terminals.
Symbols (Terminal No.)
ODLP (E8−7) ⇔ E1 (E12−1)
L (E8−8) ⇔ E1 (E12−1)
2 (E8−9) ⇔ E1 (E12−1)
D (E8−10) ⇔ E1 (E12−1)
R (E8−11) ⇔ E1 (E12−1)
SPD (E8−17) ⇔ E1 (E12−1)
SFTD (E8−21) ⇔ E1 (E12−1)
SFTU (E8−22) ⇔ E1 (E12−1)
P (E9−6) ⇔ E1 (E12−1)
N (E9−7) ⇔ E1 (E12−1)
ODMS (E9−16) ⇔ E1 (E12−1)
SLT+ (E10−17) ⇔ SLT−
(E10−16)
THO (E10−30) ⇔ E2 (E10−28)
DSL (E11−11) ⇔ E1 (E12−1)
S4 (E11−13) ⇔ E1 (E12−1)
2005 CELICA (RM1131U)
DIAGNOSTICS
E11
E12
Wiring Color
O/D main switch ON (O/D OFF)
BR−Y ⇔ BR
O/D main switch OFF (O/D ON)
IG switch ON and Shift lever L position
Y−B ⇔ BR
IG switch ON and Shift lever other than L position
IG switch ON and Shift lever 2 position
L−O ⇔ BR
IG switch ON and Shift lever other than 2 position
IG switch ON and Shift lever D position
L−W ⇔ BR
IG switch ON and Shift lever other than D position
IG switch ON and Shift lever R position
R−B ⇔ BR
IG switch ON and Shift lever other than R position
W−R ⇔ BR
IG switch ON and Turn one front wheel slowly
IG ON and "Down" transmission shift switch pressed
P−L ⇔ BR
IG ON and "Down" transmission shift switch repressed
IG ON and "UP" transmission shift switch pressed
L−R ⇔ BR
IG ON and "UP" transmission shift switch repressed
IG switch ON and Shift lever P position
P ⇔ BR
IG switch ON and Shift lever other than P position
IG switch ON and Shift lever N position
P−L ⇔ BR
IG switch ON and Shift lever other than N position
IG switch ON
BR−R ⇔ BR
IG switch ON and Press continuously O/D main switch
Y−L ⇔ Y−G
IG switch ON
GR−L ⇔ BR
ATF temperature: 110 _C (230 _F) or more
IG switch ON
P−L ⇔ BR
Vehicle driving under lock−up position
IG switch ON
O/D gear
Y ⇔ BR
Except O/D gear
AUTOMATIC TRANSAXLE (U240E)
Condition
894
E8
E9
STD Voltage
Below 3 V
9 − 14 V
10 − 14 V
Below 1 V
10 − 14 V
Below 1 V
10 − 14 V
Below 1 V
10 − 14 V
Below 1 V
Pulse signal is output
Below 1 ↔ 4−6 V
Below 1 V
10 − 14 V
Below 1 V
10 − 14 V
10 − 14 V
Below 1 V
10 − 14 V
Below 1 V
10 − 14 V
Below 1 V
10 − 14 V
Below 1.5 V
Below 1 V
10 − 14 V
Below 1 V
10 − 14 V
Below 1 V
DI4ZQ−10
D11582

Hide quick links: