Accessory Module Connections - Allen-Bradley Kinetix 5700 User Manual

Hide thumbs Also See for Kinetix 5700:
Table of Contents

Advertisement

Accessory Module
Connections
Follow these guidelines when wiring the 2198-CAPMOD-2240 capacitor
module, 2198-CAPMOD-DCBUS-IO extension module, and
2198-DCBUSCOND-RP312 DC-bus conditioner module:
• Wire module status (MS) output connections to digital input Bus
Capacitor OK, Bus Conditioner OK, or the Logix 5000™ controller
(optional).
• Flexible bus-bars (included with 2198-CAPMOD-DCBUS-IO
extension modules) are required whenever two accessory modules are
mounted side-by-side in 208 A systems. If your system does not include
the extension module, order the 2198-KITCON-DCBUSCOND or
2198-KITCON-CAPMOD2240 replacement kit.
• Refer to
DC-bus Power Supply with Capacitor Module
on
page
345.
• Refer to
Regenerative Bus Supply with DC-bus Conditioner Module
wiring example on
• Refer to
Kinetix 5700 Accessory Module Status Indicators
for troubleshooting the module status indicators and relay output.
IMPORTANT To improve system performance, run wires and cables in the wireways as
established in
shared-bus connection system.
Figure 122 - MS Connector Wiring (capacitor module and DC-bus conditioner module)
MOD
DC BUS
MODULE
STATUS
Table 98 - Accessory Module Connector Specifications
Connector
Pin
Description
MS-1
Module Status
MS-2
PELV/SELV
CP-1
24V power (plug)
CP-2
DC-bus power
Bus-bar
Bus-bar
DC-bus studs
Lugs
(1)
DC bus connections are always made from one drive module to another over the shared-bus connection system. These terminals
do not receive discrete wires.
(2) Strip length for the DC-bus studs depend on the customer-supplied lugs.
Rockwell Automation Publication 2198-UM002G-EN-P - February 2019
Connect the Kinetix 5700 Drive System
page
349.
Chapter
2. Connections to the DC bus must be made with the
2198-CAPMOD-2240 Capacitor Module or
2198-DCBUSCOND-RP312 DC-bus Conditioner Module
Module Status
2
(MS) Connector Plug
1
Recommended
Wire Size
Signal
2
mm
(AWG)
MS
0.14...1.5
MS
(28...16)
24V+
0.5...4
24V-
(20...12)
(1)
N/A
DC-
N/A
DC+
53.5 (1/0 AWG) 104 A
152 (300 kcmil) 208 A
Chapter 5
wiring example
on
page 279
Strip Length
Torque Value
mm (in.)
N•m (lb•in)
0.22...0.25
7.0 (0.28)
(1.9...2.2)
0.22...0.25
7.0 (0.28)
(1.9...2.2)
(1)
(1)
N/A
N/A
N/A
18 (156)
(2)
N/A
181

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents