Note Information
1
For power wiring specifications, refer to
2
For input fuse and circuit breaker sizes, refer to
3
For fuse and circuit breaker sizes and other 8720MC-RPS specifications, see the 8720MC Regenerative Power Supply User Manual, publication 8720MC-RM001.
4
The iTRAK® power supply must have three-phase power sourced from grounded-wye power distribution.
5
AC (EMC) line filter is required for CE compliance. Place line filter as close to the drive as possible and do not route very dirty wires in wireway. If routing in wireway is
unavoidable, use shielded cable with shields grounded to the drive chassis and filter case. For AC line filter specifications, refer to Kinetix Servo Drives Specifications
Technical Data, publication KNX-TD003. 2198-DBRxx-F line filters are preferred.
6
Terminal block is required to make connections.
7
Cable shield clamp must be used to meet CE requirements with Bulletin 2090 power cables 2 AWG and smaller. See
meet CE when wiring 2198-S263-ERSx and 2198-S312-ERSx drives with power cables larger than 2 AWG.
8
2198-Dxxx -ERSx dual-axis inverters include separate digital inputs, DSL feedback, universal feedback, motor power, and motor brake wiring plugs for each axis.
9
See
Digital Inputs Connector Pinouts
10
• When a 2198-Sxxx-ERSx single-axis inverter is the first drive module (adjacent to the 2198-CAPMOD-2240 capacitor module) you must configure the Digital Input
category in the Logix Designer application as Regeneration OK and wire the IOD connector.
• When a 2198-Dxxx-ERSx dual-axis inverter is the first drive module (adjacent to the 2198-CAPMOD-2240 capacitor module) and Axis 1 and 3 are used, you must
configure the Digital Input category in the Logix Designer application as Regeneration OK and wire the IOD connector for each axis.
Interconnect Diagrams
This appendix provides wiring examples and system block diagrams for your
Kinetix® 5700 system components.
Topic
Interconnect Diagram Notes
Power Wiring Examples
Capacitor Module Status Wiring Example
DC-bus Conditioner Module Status Wiring Example
Contactor Wiring Examples
Passive Shunt Wiring Examples
Active Shunt Wiring Examples
Kinetix 5700 Servo Drive and Rotary Motor Wiring Examples
Kinetix 5700 Servo Drive and Linear Actuator Wiring Examples
System Block Diagrams
This appendix provides wiring examples to assist you in wiring the
Kinetix 5700 drive system. These notes apply to the wiring examples on the
following pages.
Wiring Requirements
on
page
141.
Circuit Breaker/Fuse Selection
beginning on
page 103
for digital input configurable functions and default settings.
Rockwell Automation Publication 2198-UM002G-EN-P - February 2019
on
page
48.
Customer-supplied Motor Power Cables
A
Appendix
Page
341
343
357
357
358
359
360
362
367
373
on
page 178
to
341

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents

Save PDF