Mount the Kinetix 5700 Drive System
27.5 mm
First Mounting Hole
(typical) Upper and Lower
Mounting Hole
(all drive modules)
00.0 mm
Upper Mounting Holes
32.0 mm
Module Top, reference
176 mm
Lower Mounting Hole
345 mm
Lower Mounting Hole
420 mm
Lower Mounting Hole
465 mm
Lower Mounting Hole
Applies to only 2198-S160-ERSx
Single-axis Inverter
88

Drill-hole Pattern Calculations

Use
Figure 52
system configurations that include the 2198-Pxxx DC-bus power supply.
1. The first hole location is zero.
2. The second hole location is module width minus 55 mm.
3. The next hole location is 55 mm.
4. Repeat
Figure 52 - DC-bus Power Supply Mounting Hole Patterns
45.0 mm See Mounting Hole Pattern Calculations
100 mm
100 mm
Wide Module
Wide Module
Rockwell Automation Publication 2198-UM002G-EN-P - February 2019
to calculate the left-to-right hole pattern for Kinetix 5700 drive
step 2
and
step 3
for the remaining holes.
45.0 mm See Mounting Hole Pattern Calculations
30.0 mm See Mounting Hole Pattern Calculations
85 mm
55 mm
Wide Module
Wide Module
Applies to 2198-P141, 2198-P208 Power Supplies
2198-S086-ERSx and 2198-S130-ERSx Inverters,
and 2198-D057-ERSx Inverters
Applies to only 2198T-W25K-ER
iTRAK Power Supply
Ø 6.0 mm Typical
Module Top, reference
55 mm
Wide Module
Applies to only
2198-CAPMOD-DCBUS-IN
Extension Module
Ø 6.0 mm
Typical
Applies to 2198-P031 and 2198-P070 Power Supplies
2198-D006-ERSx, 2198-D012-ERSx,
2198-D020-ERSx, and 2198-D032-ERSx, Inverters
2198-CAPMOD-2240 Capacitor Module
2198-DCBUSCOND-RP312 DC-bus Conditioner Module