Table 133 - DC-bus Power Supply Behavior, FLT Sxx Fault Codes (continued)
Exception Fault Code
FLT S31 – BUS REG FAILURE
FLT S32 – BUS CAPACITOR MODULE FAILURE
FLT S35 – BUS OVERVOLT FL
FLT S40 – BUS POWER SHARING FAULT
FLT S61 – ENABLE INPUT
(1) Supported when shunt thermal switch is connected to the power supply digital input and configured in the Logix Designer application.
Table 134 - DC-bus Power Supply Behavior, FLT Mxx Fault Codes
Exception Fault Code
(1)
FLT M12 – POWER CYCLE FL
FLT M26 – RUNTIME ERROR
(1) Single-axis and dual-axis drives assert Bus Power Sharing Exception.
Table 135 - DC-bus Power Supply Behavior, NODE FLT Fault Codes
Exception Fault Code
NODE FLT 01 – LATE CTRL UPDATE
NODE FLT 02 – PROC WATCHDOG
NODE FLT 03 – HARDWARE
NODE FLT 05 – CLOCK SKEW FLT
NODE FLT 06 – LOST CTRL CONN
NODE FLT 07 – CLOCK SYNC
NODE FLT 09 – DUPLICATE IP ADDRESS
Exception Text
Bus Regulator Failure
Bus Capacitor Module Failure
Bus Overvoltage Factory Limit Fault
Bus Power Sharing Fault
Enable Input Deactivated
Exception Text
Converter Precharge Overload Factory Limit Fault
Runtime Error
Permanent
Exception Text
Magnet Motor
Control Connection Update Fault
X
Processor Watchdog Fault
X
Hardware Fault
X
Clock Skew Fault
X
Lost Controller Connection Fault
X
Clock Sync Fault
X
Duplicate IP Address Fault
X
Rockwell Automation Publication 2198-UM002G-EN-P - February 2019
Troubleshoot the Kinetix 5700 Drive System
Fault Action
–
–
X
X
–
–
–
–
–
–
Fault Action
–
–
–
–
Fault Action
Induction
Motor
X
–
–
–
X
–
–
–
X
–
–
–
X
–
–
–
X
–
–
–
X
–
–
–
X
–
–
–
Chapter 7
–
X
X
X
–
X
–
X
–
X
–
X
–
X
Best Available
Stopping Action
(applies to major faults)
X
Decel/Disable
X
Disable/Coast
X
Disable/Coast
X
Decel/Disable
X
Decel/Disable
X
Decel/Disable
X
Disable/Coast
285
Need help?
Do you have a question about the Kinetix 5700 and is the answer not in the manual?