Chapter 2
Plan the Kinetix 5700 Drive System Installation
DC-bus Power Supply
Cat. No.
2198-P031
2198-P070
2198-P141
2198-P208
2198-P208 (2 in parallel)
2198-P208 (3 in parallel)
(1) The use of 2198-DBRxx-F line filters provide a maximum motor-power cable length of up to 1200 m (3937 ft). Maximum motor-power cable length with 2198-DBxx-F line filters is 400 m (1312 ft).
(2) See
Chapter 5
beginning on
page
127, for more information on maximum cable lengths and how the use of 2198-DBRxx-F line filters affect ground screw/jumper settings. See Kinetix Servo Drive
Specifications Technical Data, publication KNX-TD003, for AC line filter specifications.
(3) When using 2198-DBRxx-F line filters with DC-bus power supplies, remove all inverter ground jumpers to reduce overall system leakage-inductance current.
(4) When using 2198-DBRxx-F line filters with regenerative bus supplies, remove all inverter ground jumpers to prevent permanent damage to the inverters.
IMPORTANT Use 2198-DBxx-F line filters only as field replacements in existing installations that use DC-bus power supplies and have
inverter ground jumpers installed. Select 2198-DBRxx-F line filters for all new systems and remove inverter ground jumpers.
2198-DBRxx-F line filters can also be used to replace existing 2198-DBxx-F line filters, but you must remove the inverter ground
jumpers.
44

AC Line Filter Selection

An AC line filter is required to meet CE requirements. Install an AC line filter
for input power as close to the 2198-Pxxx DC-bus power supply or
2198-RPxxx regenerative bus supply as possible.
IMPORTANT AC line filters are only recommended with grounded WYE power
Table 8 - AC Line Filter Selection
(1) (2) (3)
AC Line Filter
Cat. No.
• 2198-DBR20-F or
• 2198-DB20-F
• 2198-DBR40-F or
• 2198-DB42-F
• 2198-DBR90-F or
• 2198-DB80-F
• 2198-DBR200-F or
• 2198-DB290-F
Rockwell Automation Publication 2198-UM002G-EN-P - February 2019
configurations. For facility power configuration examples, see
Configurations for Kinetix 5700 Power Supplies
Regenerative Bus Supply
Cat. No.
2198-RP088
2198-RP200
2198-RP263
2198-RP312
Input Power
on
page
129.
(1) (2) (4)
AC Line Filter
Cat. No.
2198-DBR40-F
2198-DBR90-F
2198-DBR200-F

Hide quick links: