Shared DC-bus
Configurations
Size Multi-axis Shared-bus Configurations
This appendix provides information and examples for sizing your
Kinetix® 5700 drive system power supplies and inverters in multi-axis shared-
bus configurations.
Topic

Shared DC-bus Configurations

System Sizing Guidelines
System Sizing Example
System Sizing Application Example
You can supply power to your Kinetix 5700 shared DC-bus system
configuration from following sources:
• Single 2198-Pxxx DC-bus power supply
• Multiple 2198-P208 DC-bus power supplies (up to three are possible)
• Single 2198-RPxxx regenerative bus supply
• Multiple 8720MC-RPS regenerative power supply

Shared DC-bus Definitions

Throughout this manual, these terms are used to describe how drive modules
are grouped together.
Table 173 - Shared-bus Terminology
Term
Definition
DC-bus group
Drive modules that are all connected to the same DC bus.
Group of power supply and/or drive modules that are directly connected together via
Cluster
Kinetix 5700 DC bus-bars only.
Group of drive modules that are directly connected together via Kinetix 5700 DC bus-bars
Extended cluster
and connected to the power supply cluster via customer-supplied DC-bus cable.
Power supply cluster
The cluster that contains the AC to DC converter (power supply).
When 2 drive clusters are part of the same DC-bus group joined by the DC bus-bars and
Extended DC-bus
customer-supplied DC-bus cable.
Rockwell Automation Publication 2198-UM002G-EN-P - February 2019