Regenerative Bus Supply Input Power Configurations; Typical Regenerative Bus Configuration Examples - Allen-Bradley Kinetix 5700 User Manual

Hide thumbs Also See for Kinetix 5700:
Table of Contents

Advertisement

Regenerative Bus Supply
Input Power Configurations
Active Shunt (optional component)
See
External Active-shunt Connections
on
page 183
for more information.
1606-XLxxx
24V DC Control, Digital Inputs, and
Motor Brake Power (customer-supplied)
AC Input Power
Kinetix 5700 Servo Drive System
Converter Digital Inputs
Magnetic Contactor (M1) Control String
324...506V AC
Three-phase Input Power
Line Disconnect
Device
Circuit
Protection
Magnetic (M1)
Contactor
The 2198-RPxxx regenerative bus supply (24...140 kW) provides full-line
motoring and regenerative power to and from the Kinetix 5700 drive system.
In addition, you can extend the DC-bus voltage to additional inverter clusters
via accessory modules.

Typical Regenerative Bus Configuration Examples

In this example, the inverter modules are mounted to the right of the
regenerative bus supply. One single-axis (inverter) module and three dual-axis
(inverter) modules support seven axes of motion. Other features include:
• Digital inputs are wired to sensors and the control circuitry at the IOD
connectors.
• The contactor enable relay protects the regenerative bus supply in the
event of shutdown fault conditions.
• The DC-bus conditioner module is required when the combined motor
cable length exceeds 400 m (1312 ft). See
on
page 59
Figure 5 - Typical Shared DC-bus Installation (mounted left to right)
DC–
DC+
Allen-Bradley
1606-XL
Powe r S u p p l y
Input
(1)
Regenerative Bus Supply
(front view)
MOD
NET
2
1
I/O
1
6
OK+
OK–
EN–
EN+
5
10
D+
D-
2198-DBRxx-F
AC Line Filter
(required for CE)
(1) The regenerative bus supply can be left or right of the inverters. Further, we recommend that the highest inverter power ratings
are positioned closest to the regenerative bus supply and in decreasing order leading away from the regenerative bus supply.
Rockwell Automation Publication 2198-UM002G-EN-P - February 2019
for more information on accessory module requirements.
1
9
1
9
1
9
1
9
SB+/NC
SB+/NC
SB+/NC
SB+/NC
S1A
S1A
S1A
S1A
SCA
SCA
SCA
SCA
S2A
S2A
S2A
S2A
SB-
SB-
SB-
SB-
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
16
8
8
16
8
16
8
16
Single-axis
Inverter
Dual-axis Inverters
MOD
MOD
MOD
MOD
MOD
NET
NET
NET
NET
DC BUS
2
2
2
2
1
1
1
1
I/O
I/O-A
I/O-B
I/O-A
I/O-B
I/O-A
I/O-B
1
6
1
6
1
6
1
6
1
6
1
6
1
6
MODULE
STATUS
5
10
5
10
5
10
5
10
5
10
5
10
5
10
UFB-A
UFB-B
UFB-A
UFB-B
UFB-A
UFB-B
UFB
D+
D+
D+
D+
D+
D+
D-
D-
D-
D-
D-
D-
MF-A
MF-B
MF-A
MF-B
MF-A
MF-B
MF
-
MBRK
+
Bonded Cabinet
Ground Bus
Start
Accessory Module Selection
Kinetix 5700 Servo Drive System
(top view)
Shared DC-bus Power
Shared 24V Control Power
(24V shared-bus connection system is optional)
Shared-bus connection system for DC-bus and
24V DC control power.
Inverter Digital Inputs
DC-bus Conditioner
Module
Chapter 1
23

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents

Save PDF