Chapter 6
Configure and Start the Kinetix 5700 Drive System
Menu/Sub Menu
Attributes
Selections
Catalog number
Firmware revision
Module Info
Hardware revision
Serial number
Bus diagnostics
Output 1 diagnostics
Diagnostics>
Converter
Diagnostics
Output 2 diagnostics
Converter diagnostics
Fault text
Fault Log
Fault details
Fault help
192
Table 104 - Navigating the iTRAK Power Supply Menu
Description
Fault code as listed in
Fault Codes
on
page
277.
The problem as reported in
Fault Codes
on
page 277
The Possible Solution as reported in
Fault Codes

Setup Screens

The setup screens provide the means of changing drive settings, for example,
the IP address. Press one of the setup buttons to access the setup screens.
You can use the soft menu items and navigation buttons to
view the information and make changes.
Press
to validate your changes:
• If the change is invalid, the value doesn't change.
• If the change is valid, an asterisk appears next to the
changed attribute.
IMPORTANT You must cycle control power to make network configuration changes
Rockwell Automation Publication 2198-UM002G-EN-P - February 2019
Example Values
2198T-W25K-ER
FW: 6.1.7100254
HW REV: 1.1
SERIAL#: xxxxxxxxxxx
BUS VOLT: 0.0V
OUT1 VOLT: 0.0V
OUT1 AMPS: 0.0A
OUT1 PWR: 0.0kW
OUT1 UTIL: 0.0%
OUT2 VOLT: 0.0V
OUT2 AMPS: 0.0A
OUT2 PWR: 0.0kW
OUT2 UTIL: 0.0%
TOTAL PWR: 0.0kW
FLT S38 - FUSE BLOWN
The internal DC-bus power fuse is blown
on
page
277.
Return drive for repair if fault continues
persistent. In this example, the IP address was changed. The change
takes affect and the asterisk disappears after control power is cycled.
Display configuration changes take effect immediately.
SETTINGS
NETWORK
DISPLAY
STATIC IP
IP ADDRESS*
SUBNET MASK