Wiring Guidelines

Wire the Power Connectors

Use these guidelines as a reference when wiring the power connectors on your
Kinetix 5700 drive modules.
IMPORTANT For connector locations of the Kinetix 5700 drive modules, refer to
Kinetix 5700 Connector Data
When removing insulation from wires and tightening screws to secure the
wires, refer to the table on
IMPORTANT To improve system performance, run wires and cables in the wireways as
established in
Follow these steps when wiring the connectors for your Kinetix 5700 drive
modules.
1. Prepare the wires for attachment to each connector plug by removing
insulation equal to the recommended strip length.
Some cables come prepared with wires appropriately stripped.
IMPORTANT Use caution not to nick, cut, or otherwise damage strands as you
2. Route the cable/wires to your Kinetix 5700 drive module connector.
3. Insert wires into connector plugs.
Refer to the connector pinout tables in
diagrams in
Appendix
4. Tighten the connector screws.
5. Gently pull on each wire to make sure it does not come out of its
terminal; reinsert and tighten any loose wires.
6. Insert the connector plug into the drive module connector.
This section provides examples and guidelines to assist you in making
connections to the input power connectors.
Refer to
Power Wiring Examples

Wire the 24V Control Power Input Connector

The 24V power (CP) connector requires 24V DC input for the control
circuitry. The connector plug ships with the drive module and shared-bus
connector kits are purchased separately.
IMPORTANT Mount the 24V power supply as close to the drive system as possible to
minimize voltage drop on the 24V input power wiring.
Rockwell Automation Publication 2198-UM002G-EN-P - February 2019
Connect the Kinetix 5700 Drive System
on
page
94.
page 141
for strip lengths and torque values.
Establishing Noise Zones
on
remove the insulation.
Chapter 4
A.
on
page 343
for interconnect diagrams.
Chapter 5
page
70.
or the interconnect
145