Accessory Module Flowcharts

The following flowcharts are designed to help you determine the minimum
number of accessory modules that are needed for your application.
IMPORTANT Specific system demands can justify additional accessory modules based on
the previously mentioned benefits.
In this flowchart, a 2198-Pxxx DC-bus power supply or 2198-RPxxx
regenerative bus supply supplies DC-bus power to a single cluster of drives.
System variables that you need to know include the following:
• The type of AC to DC converter used
• The input power ground configuration
• The total motor cable length
Figure 34 - Single-cluster Drive System
Start
What type of AC to DC
converter is used?
Regenerative Bus
Supply
Yes
Is this an impedance
grounded system?
No
What is the total motor
cable length?
≥400 m
(1312 ft)
DC-bus Conditioner Module
Rockwell Automation Publication 2198-UM002G-EN-P - February 2019
Plan the Kinetix 5700 Drive System Installation
DC-bus Power
Supply
No accessory
<400 m
modules required.
(1312 ft)
Chapter 2
65