Input Power (IPD) Connector Plug
21mm (4 AWG-250 kcmil)
15-20 Nm (132-177 lbin)
Input Power (IPD) Connector
Screws (3x): 6 mm Hex Driver
Torque: 15...20 N•m (132...177 lb•in)
Regenerative Bus Supply
DC-bus Power Supply
Cat. No.
Cat. No.
2198-P031
2198-RP088
2198-P070
2198-P141
2198-RP200
2198-P208
2198-RP263
2198-RP312

Wire the Input Power Connector

The input power (IPD) connector applies to the 2198-Pxxx DC-bus power
supply and 2198-RPxxx regenerative bus supply.
Figure 95 - IPD Connector Wiring
Front View
L1
L2
L3
2
Input Power Ground Terminal
Screw: 8 mm Hex Driver
Torque: 5.6 N•m (50 lb•in)
Table 72 - Input Power (IPD) Connector Specifications
Pin
L3
L2
L1
Rockwell Automation Publication 2198-UM002G-EN-P - February 2019
ATTENTION: Make sure the input power connections are correct when
wiring the IPD connector plug. Insert the plug into the module connector
and tighten screws to the specified torque value. Incorrect wiring/polarity or
loose wiring can cause damage to equipment.
Connector Screws (2)
0.8 N•m (7.1 lb•in)
Bottom View
L1
L2
L3
The IPD connector on 2198-RP263
and 2198-RP312 power supplies is
not removable.
Recommended
Wire Size
Signal
2
mm
6...10
(10...8)
10...35
L3
(8...2)
L2
L1
21.1...120
(4...250 kcmil)
Connect the Kinetix 5700 Drive System
2198-Pxxx DC-bus Power Supply or
2198-RP088 and 2198-RP200
Regenerative Bus Supply, Bottom View
(DC-bus power supply is shown)
L1
L2
L3
2198-RP263 and 2198-RP312
Regenerative Bus Supply,
Bottom View
Strip Length
mm (in.)
(AWG)
10.0 (0.39)
20.0 (0.79)
27.0 (1.06)
Chapter 5
Torque Value
N•m (lb•in)
0.8 (7.1)
15...20
(132...177)
147