Wire Motor Power And Brake Connectors - Allen-Bradley Kinetix 5700 User Manual

Hide thumbs Also See for Kinetix 5700:
Table of Contents

Advertisement

Chapter 5
Connect the Kinetix 5700 Drive System
Wire Motor Power and Brake
Connectors
152
Motor power connections are made at the MP connector on the bottom of the
dual-axis and single-axis inverters. Motor brake connections are made at the
BC connector. On dual-axis inverters, the BC connectors are on either side of
the MP connectors on the bottom of the drive. On single-axis inverters, the
BC connector is on the front of the drive.
• On 2198-S086-ERSx, 2198-S130-ERSx, and 2198-S160-ERSx single-
axis inverters, the motor power connector and shield clamp are mounted
to a separate bracket that plugs into the bottom of the drive and has
mounting screws to hold it secure.
Motor Power Connector
• On 2198-S263-ERSx and 2198-S312-ERSx single-axis inverters, the
motor power connector is part of the drive. The clamp bracket is
included with the drive, but requires some assembly.
Hole for M8 Stud
IMPORTANT The clamp included with 2198-S263-ERSx and 2198-S312-ERSx inverters is
compatible with Bulletin 2090 (4 and 2 AWG) motor power cable. Do not use
the clamp for smaller or larger cables.
Rockwell Automation Publication 2198-UM002G-EN-P - February 2019
2198-S086-ERSx,
2198-S130-ERSx, and
2198-S160-ERSx
Single-axis Inverter Clamp Bracket
Bracket
(side view)
Clamp
2198-S263-ERSx and
2198-S312-ERSx
Single-axis Inverter Clamp Bracket
Bracket
(front view)
Clamp