Configure Extended Speed Operation

The extended speed feature is only configurable with Kinetix 5700 drives and
Kinetix VP continuous-duty IPM motors. You can configure the Extended
Speed feature in Axis Properties>Motor category of the Logix Designer
application (version 29.00 or later).
Follow these steps to enable operating at speeds greater than the Bus
Overvoltage Speed.
1. In the Extended Speed field, check Extended Speed Permissive.
2. Set the Max Extended Speed attribute as required by your application.
WARNING: Operation at speeds exceeding the Bus Overvoltage Speed
requires use of an auxiliary device to protect the DC bus system from an
overvoltage condition.
Rockwell Automation Publication 2198-UM002G-EN-P - February 2019
Motor Control Feature Support
Appendix E