External Shunt Module Connections; Sercos Fiber-Optic Cable Connections - Allen-Bradley 2099-BM06-S User Manual

High power servo drive
Hide thumbs Also See for 2099-BM06-S:
Table of Contents

Advertisement

External Shunt Module
Connections
SERCOS Fiber-optic Cable
Connections
External active shunt modules listed in the table on page 156 are compatible with
Kinetix 7000 drives. Follow these guidelines when wiring your external active
shunt module kit.
• Refer to Shunt Resistor on page
recommendations.
• Refer to
Appendix B
• Refer to the installation instructions provided with your shunt module.
When tightening screws to secure the wires to the DC bus terminals, see
IMPORTANT
Table 36
This procedure assumes you have your Logix SERCOS interface module/PCI
card and Kinetix 7000 drive mounted and are ready to connect the fiber-optic
cables.
The SERCOS fiber-optic ring is connected using the SERCOS receive (Rx) and
transmit (Tx) connectors.
See page
65
to locate the SERCOS connectors on your Kinetix 7000 drive. See
the figure below to locate the connectors on your SERCOS interface module or
PCI card.
Plastic cable is available in lengths up to 32 m (105 ft). Glass cable is available in
lengths between 50 m (164 ft) and 200 m (656 ft).
When connecting Kinetix 7000 drives, use at least a 2090-SCEP1-0, 1 m (3
IMPORTANT
ft) or longer cable.
Larger drives may require longer cables.
Rockwell Automation Publication 2099-UM001D-EN-P - December 2012
Connect the Kinetix 7000 Drive System
37
for important wiring
for the Kinetix 7000 drive interconnect diagrams.
on page
90
for torque values.
Chapter 4
101