17.5.3 Data transfer direction specification function
The data transfer direction can be changed by using the DIRn bit of the CSIM3n register (n = 0, 1).
(1)
MSB first (DIRn bit = 0)
Figure 17-12: Data Transfer Direction Specification (MSB first)
(a) Transfer direction: MSB first, Transfer data length: 8 Bits
SCK3n (I/O)
SI3n (input)
SO3n (output)
SO3n
(c) Reading from CSIBUFn register or SFDB3n register
CSIBUFn or SIRB3n
μPD70F3187:
Remark:
μPD70F3447:
Chapter 17 Clocked Serial Interface 3 (CSI3)
DI7
DI6
DO7
DO6
(b) Writing from SFDB3n register to CSIBUFn register
15
SFDB3n
CSIBUFn
Data
15
SFDB3n
Undefined value
(read value)
SO3n
n = 0, 1
n = 0
User's Manual U16580EE3V1UD00
DI5
DI4
DI3
DO5
DO4
DO3
8 7
0
00H
SIO3n
8 7
Data
SIO3n
DI2
DI1
DO2
DO1
SI3n
0
SI3n
DI0
DO0
697