Program
Program Name/Description
Number
IPL Basic Setup – RTCP Port Number (RTP
84-26-03
Port Number + 1)
Assign the RTCP port number to be used for
each DSP on the GPZ-IPLE.
IP Phone Configuration:
Program
Program Name/Description
Number
Basic Extension Data Setup – Extension
15-01-01
Name
Define the extension/virtual extension name.
IP Telephone Terminal Basic Data Setup – IP
15-05-02
Phone Fixed Port Assignment
MAC Address of registered MLT SIP phone is
stored and/or can input the MAC address of an
MLT SIP phone so when it comes online it is
provided with the extension which the MAC
address matches.
IP Telephone Terminal Basic Data Setup –
15-05-07
Using IP Address
Review the registered IP Phones IP Address
[Informational Only].
IP Telephone Terminal Basic Data Setup –
15-05-15
CODEC Type
Assign the registered IP Phone Codec type of
the MLT SIP – Reference Program 84-11 Dterm
IP Codec Basic Information.
15-05-16
Authentication Password
Assign the authentication password for SIP
single line telephones.
IP Telephone Terminal Basic Data Setup – IP
15-05-18
Duplication Allowed Group
For an adapter that has one IP address coming
into it but multiple extensions off of it. Enable
this option for all extensions in the group so the
CPU knows that the one IP Address is assigned
to multiple extensions.
IP Telephone Terminal Basic Data Setup –
15-05-40
Calling Name Display Info via Trunk for
Standard SIP
Sets the incoming calling name display type on
a standard SIP terminal. Trunk name is the first
priority and abbreviated (SPD) name is second
priority.
Input Data
0 ~ 65534
Input Data
Maximum of 12 characters.
MAC address
00-00-00-00-00-00 to
FF-FF-FF-FF-FF-FF
0.0.0.0 ~ 255.255.255.255
1- Type 1
2- Type 2
3- Type 3
4- Type 4
5- Type 5
Maximum of 24 characters.
0 = Disable
1 = Enable
0 = Both name and number
1 = Name only
2 = Number only
3 = None
1394
Default
VoIP GW1 =
10021
Default
STA 101 = Ext
101
STA 102 = Ext
102, etc.
00-00-00-00-00-
00
0.0.0.0
1
No Setting
0
0