Connect the Alarm Relay Output

The ES7506 provides one alarm relay
output. The relay contacts are
energized (open) for normal operation
and close under error conditions that
include:
Dry output
Power failure
Link failure
Ping failure
Super Ring failure
The alarm relay can be configured in
one of the ES7506 user interfaces
(Warning
on Page 81) or through the Command Line Interface
Wiring the alarm relay output is the same as wiring power inputs in
9.
1. Insert the positive and negative wires (12-24 AWG) into V+ and V-.
2. Tighten the wire-clamp screws to prevent the wires from coming loose.

Mount the ES7506

You can use the following procedure to mount the
ES7506 on a DIN rail or on the wall.
Note: The ES7506 will disperse heat through the metal
case during PoE port operation. The ES7506
should be installed and mounted onto a panel
which provides good heat dispersion.
DIN Rail Mounting
Two DIN rail clips and four screws are shipped
with theES7506. Use the screws to attach the
DIN rail clip to the wall-mount plate.
RocketLinx ES7506 User Guide: 2000529 Rev. F
(Global Configuration Mode
Connect the Power and Ground
Attaching the ES7506 On a Wall
Use the hook holes located at the corners
of the wall-mount plate to mount the ES706.
Connect the Alarm Relay Output - 11
Hardware Installation
on Page 103).