Waveform Log Retrieval - Electro Industries Shark 200 Installation & Operation Manual

Upgradeable fully featured power & energy meter
Hide thumbs Also See for Shark 200:
Table of Contents

Advertisement

03 E8
00 01
00 05
00 00
00 00
00 00
B.5.7: Waveform Log Retrieval
The waveform log is unique among the logs in that each capture is composed of 26
waveform records, and each record requires 4 windows to retrieve. For more informa-
tion on record retrieval, see B.5.4.3: Log Retrieval Procedure on page B-18. The 26
waveform records adhere to the following byte-map.
SIZE
6 bytes
1 byte
1 byte
962 bytes
Electro Industries/GaugeTech
Electro Industries/GaugeTech
The Leader In Power Monitoring and Smart Grid Solutions
The Leader In Power Monitoring and Smart Grid Solutions
- 100.0% (Fundamental)
- 0.1%
- 0.5%
- 0.0%
- 0.0%
- 0.0%
CONTENT
Timestamp
All 26 records have
the same time-
stamp
Capture Number
All 26 records have
the same capture
number
Record Number
Records are num-
bered 0-25
Record Payload
Waveform Record
payload. All 26
Waveform Record
Payloads com-
bined create a
Waveform Capture
Doc