Summary of Contents for Electro Industries WARMFLO WF-ANZ7

  • Page 1 ® ANALYZER WF-ANZ7 NEW UNIT FOR FORCED AIR & TS BOILERS Warranty XX017 HI010...
  • Page 2 Table of Contents Configuration Information ………………………………….. 3 Forced Air ……………………………………………………… 5 Forced Air CFM ……………………………..………………… 9 TS Boiler EB-S, EB-CA, EB-CO, EB-MS ………………………. 10 EB-WA, EB-WO, EB-MA, EB-MO …………………… 12 04/24/2009 HI010...
  • Page 3 WarmFlo V4.xx Handheld Configuration Information – Read First This is an upgrade for the WF-ANZ5, but this unit complies with all WarmFlo units shipped. - Original board with 28-pin chip - WarmFlo II board with 40-pin chip - WarmFlo Plus board with 40-pin chip - WarmFlo Select board with 40-pin chip - WarmFlo TS Boiler with 40-pin chip EB boards include:...
  • Page 4 WarmFlo V4.xx Handheld The keyboard, “SHIFT” is to allow added control functions. Similar to a typewriter keyboard, “SHIFT” refers to the upper designated key function and must be held down while pressing the other key. Read Mode: 1) Press and hold the ‘SHIFT’ key, then press the ‘READ’ key to enter the read mode. 2) Pressing 'MON' at any time will go to the real time monitor mode.
  • Page 5 Forced Air WARMFLO II WARMFLO PLUS WARMFLO SELECT POWER-UP "OUTDOOR 57°F" 'MON' "DESIRED 90°F" " PRESS MON " "SUPPLY 62°F" "PWM RATIO 100%" 'MON' 'READ' 'READ' (± Temperature Offset) "OT 57°F t t t °F" 'PREV' "ST 62°F t t t °F" (±...
  • Page 6 Forced Air Monitor Mode: 1) Pressing 'READ' at any time will go to the data entry or read mode. 2) Use the 'MON' key to toggle between the 2 displays. 3) The displayed data is automatically updated every 7 seconds. While in the monitor mode you can also hold the ‘SHIFT’...
  • Page 7 Forced Air STG 1-4 OT DIS (Stage 1-4 OT Disable Temperature) (Enter a temperature within the range of -40°F to +185°F) The OT sensor is used to determine summer or air conditioning function and keeps the electric elements and stand-by off even though there may be a Y input.
  • Page 8 Forced Air CT STG DISABLE (Software version 10.xx, 12.xx or 18.xx only) (Enter 0, 1, 2, 3 or 4) Enter one or two stage numbers to disable when the CT input senses 10 amps or more. These stages will turn OFF immediately. When the CT input senses 5 amps or less, the stages will be re-enabled and come back ON if necessary.
  • Page 9 Forced Air - CFM - WARMFLO II WARMFLO PLUS POWER-UP WARMFLO SELECT "OUTDOOR 57°F" 'MON' "DESIRED 90°F" " PRESS MON " "SUPPLY 62°F" "PWM RATIO 100%" 'MON' 'SHIFT 9' "RETURN TEMP 095" 'MON' "CFM = 7586.6" "TOTAL kW 12" "ST=100° RT= 95°" 'SHIFT MON' CFM mode Whenever either monitor screen is displayed, press and hold the ‘SHIFT’...
  • Page 10 TS Boiler EB-S EB-CA EB-CO EB-MS Note: TS Boiler EB-S and EB-CA models do not use the outdoor sensor so the temperature displayed for “OUTDOOR” will read “N/A”. Monitor Mode: 1) Pressing 'READ' at any time will go to the data entry or read mode. 2) Use the 'MON' key to toggle between the 2 displays.
  • Page 11 TS Boiler EB-S EB-CA EB-CO EB-MS * DELAY E LO MASS (Enter 0 to 9 minutes) Same as ‘Delay E Hi Mass’ except the set point switch settings for ‘Lo Mass’ are positions 5 thru 7. * START UP DELAY (Enter 0 to 99 seconds) This is the delay at the beginning of a ‘W’...
  • Page 12 TS Boiler EB-WA EB-WO EB-MA EB-MO Note: TS Boiler EB-WA and EB-MA models do not use the outdoor sensor so the temperature displayed for “OUTDOOR” will read “N/A”. 04/24/2009 HI010...
  • Page 13 TS Boiler EB-WA EB-WO EB-MA EB-MO Monitor Mode: 1) Pressing 'READ' at any time will go to the data entry or read mode. 2) Use the 'MON' key to toggle between the 2 displays. 3) The displayed data is automatically updated every 5 seconds. The monitor mode data consists of: OUTDOOR (Outdoor Temperature, OT) WATER (Water Temperature, WT)
  • Page 14 TS Boiler EB-WA EB-WO EB-MA EB-MO STG 1-4 OT DIS (Stage 1-4 OT Disable Temperature) (Enter a temperature within the range of -40°F to +185°F) The OT sensor is used to determine summer or air conditioning function and keeps the electric elements and stand-by off even though there may be a Y input.
  • Page 15 TS Boiler EB-WA EB-WO EB-MA EB-MO Temperature settings with OT sensor ENABLED Temperature settings with OT sensor DISABLED 04/24/2009 HI010...
  • Page 16 Limited Product Warranty Effective November 1, 2009 Electro Industries, Inc. warrants to the original owner, at the original installation site, for a period of two (2) years from date of original purchase, that the product and product parts manufactured by Electro Industries, Inc.
  • Page 17: Conditions And Limitations

    ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE HEREBY DISCLAIMED WITH RESPECT TO ALL PURCHASERS OR OWNERS. ELECTRO INDUSTRIES, INC. IS NOT BOUND BY PROMISES MADE BY OTHERS BEYOND THE TERMS OF THESE WARRANTIES. FAILURE TO RETURN THE WARRANTY CARD SHALL HAVE NO EFFECT ON THE DISCLAIMER OF THESE IMPLIED WARRANTIES.