I/O Change Log Record - Electro Industries Shark 200 Installation & Operation Manual

Upgradeable fully featured power & energy meter
Hide thumbs Also See for Shark 200:
Table of Contents

Advertisement

I/O Change Log Record:

I/O Change Log tables:
Byte
0
1
2
3
Value
Timestamp
Card Change Flags:
Bit
7
Value
Out 4
Change
Card Current States:
Bit
Value
Size: 10 bytes (16 bytes)
Data: The states of the relay and digital inputs at the time of capture for both Option
cards 1 and 2. If the option card does not support I/O Change Records (no card or not
a Digital Option Card), the value will be 0.
NOTES:
• An I/O Change log record will be taken for each Relay and Digital Input that has
been configured in the Programmable Settings to record when its state changes.
• When any one configured Relay or Digital Input changes, the values of all Relays
and Digital Inputs are recorded, even if they are not so configured.
Electro Industries/GaugeTech
Electro Industries/GaugeTech
The Leader In Power Monitoring and Smart Grid Solutions
The Leader In Power Monitoring and Smart Grid Solutions
4
5
6
Card 1 Changes
6
5
4
Out 3
Out 2
Out 1
Change
Change
Change
7
6
5
4
Out 4
Out 3
Out 2
Out 1
State
State
State
State
B: Modbus Map and Retrieving Logs
7
8
Card 1 States
Card 2 Changes
3
2
1
In 4
In 3
In 2
Change
Change
Change
3
2
1
In 4
In 3
In 2
State
State
State
#
Doc
E149701
9
Card 2 States
0
In 1
Change
0
In 1
State
B-38