7.8: Fiber Optic Communication Card (FOSTS; FOVPS)

The Fiber Optic Communication card provides a standard serial communication port
via a fiber optic connection. An echo switch is available to enable messages bypassing
the unit. This feature can be used in a daisy chained network topology.
7.8.1: Specifications
The technical specifications at 25 °C are as follows:
Number of Ports:
Power consumption:
Fiber connection:
Optical fiber details:
ST® (FOSTS)
Versatile Link (FOVPS):
Baud rate:
Diagnostic feature:
The general specifications are as follows:
Operating Temperature:
Storage Temperature:
Relative air humidity:
EMC - Immunity Interference:
Weight:
Dimensions (inch) W x H x L:
Electro Industries/GaugeTech
Electro Industries/GaugeTech
The Leader In Power Monitoring and Smart Grid Solutions
The Leader In Power Monitoring and Smart Grid Solutions
7: Using the I/O Option Cards
1
0.160 W internal
ST® (FOST) or Versatile Link (FOVP) – as per
order
Multimode
50/125 µm, 62.5/125 µm, 100/140 µm,
200 µm Hard Clad Silica (HCS®)
200 µm Hard Clad Silica (HCS®)
1 mm Plastic Optical Fiber (POF)
Up to 57.6 k b/s – pre-programmed in the main
unit
LED lamps for TX and RX activity
(-20 to +70) °C
(-40 to +80) °C
Maximum 95%, non-condensing
EN61000-4-2
1.2 oz
0.72 x 2.68 x 3.26
#
Doc
E149701
7-16