Installing A Pci Expansion Blade Into Server Chassis - Hitachi CB 520H B1 Service Manual

Compute blade 500 series
Hide thumbs Also See for CB 520H B1:
Table of Contents

Advertisement

Do not leave a slot open for a long time. Leaving it open can cause the
overheat problem for other components.

Installing a PCI expansion blade into server chassis

Note: To change configuration from half-wide server blade to PCI expansion
blade, remove the shelf from the server chassis. Refer to the
shelf in the server chassis on page 5-129
1
Put on an anti-static wrist strap.
.
2
Reverse the removal procedure.
.
3
Turn on LID LED for identifying the target blade. See
.
on/off procedure on page 4-7
4
If you need to update the BMC and/or EFI firmware, consult with Hitachi
.
Data Systems Customer Support team.
5
Restore the Blade configuration data (FRU/ BMC configuration/ EFI
.
configuration) from the automatic back up field in server chassis. See
Backup/restore procedure on page 4-30
6
BMC will restart. Wait for about 10 minutes.
.
7
Select Alerts tab and select All Logs > System Event Log, and then
.
click Refresh to identify the latest information.
8
Confirm the Server blade: BMC initialization complete message.
.
If this massage was indicated, go to next step.
9
Turn on LID LED for identifying the target blade again.
.
See
10
Execute the CBTP and check the replaced PCI expansion blade.
.
See
11
Turn off the maintenance mode from web console.
.
See
12
Restart BMC when you installed a new server blade. See
.
procedure on page
5-16
Figure 5-12 Confirming system log
Identify LED (LID) on/off procedure on page 4-7
Diagnostic procedure overview on page 8-2
Maintenance mode on/off procedure on page 4-10
4-56.
Replacing parts
Hitachi Compute Blade 500 Series System Service Manual
section.
section.
section.
section.
Replacing a
Identify LED (LID)
section.
section.
Restarting BMC