8
Wait about three minutes, and then confirm that Power LED and Status
.
LED of the FC switch module emit in green.
9
Press Enter key to display login prompt of FC switch module.
.
10
Enter admin as login name, and then press Enter key.
.
11
Enter password as password, and then press Enter key.
.
12
Enter ag --modeshow, and then press Enter key.
.
Confirm that a message "Access Gateway mode is enabled." is
indicated.
13
Skip from this step 13 when the switch monitor mode of failed FC switch
.
was Fabric mode.
Enter mapsconfig --enablemaps -policy dflt_conservative_policy,
and then press Enter key to set MAPS mode.
Enter y when "Do you want to continue? (yes, y, no, n): [no]" is
indicated, and then press Enter key.
Common process for replacement