Slot No. indicator
3
B-nn-Lz
B-nn-OB
Notes:
1
x indicates the mezzanine slot number and the value is 1 or 2.
.
2
y indicates the mezzanine slot number and the value is 1, 2, 3 or 4.
.
3
z indicates the LOM number and the value is 1 or 2.
.
Note
Update the firmware of the replaced CNA/LAN mezzanine card
according to the following criteria.
1. When the firmware version of failed CNA/LAN mezzanine card was
confirmed before the replacement, apply the confirmed version onto
the replaced Emulex CNA/LAN mezzanine card.
2. When the firmware version of failed CNA/LAN mezzanine card was
not confirmed or was indicated as No history before the replacement,
and other CNA/LAN mezzanine cards or LOM are installed in the
server blade, apply the version of other mezzanine cards or LOM.
3. When the firmware version of failed CNA/LAN mezzanine card was
not confirmed or was indicated as No history before the replacement,
and neither CNA/LAN mezzanine cards nor LOM except the replaced
CNA product is installed in the server blade, identify an appropriate
firmware version of CNA product according to the server blade type
and its firmware version. For details, see the following table.
Type
CB 520A A1
CB 520H A1/B1
CB 540A A1/B1
CB 520H B2/B3/B4
CB 520X B1/B2/B3
Perform the following steps only when the updating firmware is
required.
9
Enter 2 in Select No. line of Emulex CNA Utility dialog box, and then
.
press Enter.
Configuring Emulex mezzanine card
Hitachi Compute Blade 500 Series System Service Manual
Component
LOM
LOM
Blade
FW version
< 02-51
02-51 ≤
< 01-92
01-92 ≤
< 03-25
03-25 ≤
N/A
N/A
Server blade
CB 540A B1
CB 520X B1/B2/B3
To be applied CNA FW version
4.2.433.604
Latest version
4.2.433.604
Latest version
4.2.433.604
Latest version
Latest version
Latest version