Installing A Storage Expansion Blade - Hitachi CB 520H B1 Service Manual

Compute blade 500 series
Hide thumbs Also See for CB 520H B1:
Table of Contents

Advertisement

6
Identify F/W version and take notes of it. See
.
procedure on page 4-22
7
Loosen the thumbscrew and release blue lock tab, as shown below.
.
8
Pull the two levers on both sides, as shown below.
.
9
Holding the server blade and storage expansion blade, carefully slide out
.
from the chassis and place it on an anti-static mat.
Notice:
Do not leave a slot open for a long time. Leaving it open can cause the
overheat problem for other components.

Installing a storage expansion blade

Note: To change configuration from half-wide server blade to storage
expansion blade, remove a shelf from the server chassis. Refer to the
Replacing a shelf in the server chassis on page 5-129
1
Put on an anti-static wrist strap.
.
2
Reverse the removal procedure.
.
3
Turn on LID LED for identifying the target blade. See
.
on/off procedure on page 4-7
4
If you need to update the BMC and/or EFI firmware, consult with Hitachi
.
Data Systems Customer Support team.
5
Restore the Blade configuration data (FRU/ BMC configuration/ EFI
.
configuration) from the automatic back up field in server chassis. See
Backup/restore procedure on page 4-30
6
BMC will restart. Wait for about 10 minutes.
.
7
Select Alerts tab and select All Logs > System Event Log, and then
.
click Refresh to identify the latest information.
8
Confirm the Server blade: BMC initialization complete message.
.
5-12
Figure 5-9 Removing the storage expansion blade
Replacing parts
Hitachi Compute Blade 500 Series System Service Manual
section.