Step
4
Cooling fan module troubleshooting table
Step
1
2
11-4
Symptom
Possible Cause
-
•
Management
module.
•
Backplane.
Table 11-2 Fan module troubleshooting table
Symptom
Possible Cause
•
The Active
Fan module
LED is off or
Fault.
solid amber.
•
The console
reports FAN
failure.
•
The Active
Fan module
LED of one
Fault.
Troubleshooting
Hitachi Compute Blade 500 Series System Service Manual
Actions / Verifications
Action 2
1
Replace the suspected power supply or
.
module.
2
Reinstall all power supplies and modules
.
in the original bay.
3
Connect all power cord to the power
.
supplies, and then power on the server
chassis.
Verification 2
1
If the Power LED lit on green, the
.
replacing is completed.
2
If the Power LED indicates other than
.
normal condition, then go to step 4.
Action 1
1
See management module troubleshooting
.
table.
2
Contact with Hitachi Data Systems
.
technical support. See the Getting help
section in this manual.
Actions / Verifications
Action 1
1
Remove the failed fan module.
.
2
Inspect visually the connector for
.
damage.
3
Reinstall it to the original bay.
.
Verification 1
1
If the Active LED lit on green, then
.
replacing is completed.
2
If the Active LED remained amber,
.
then go to the following Action 2.
Action 2
1
Remove the failed fan module and
.
replace it with the spare one.
Verification 2
1
If the Active LED lit on green, then
.
replacing is completed.
2
If the Active LED remained amber,
.
then go to step 3.
Action 1