Cooling Fan Module Troubleshooting Table - Hitachi CB 520H B1 Service Manual

Compute blade 500 series
Hide thumbs Also See for CB 520H B1:
Table of Contents

Advertisement

Step
4

Cooling fan module troubleshooting table

Step
1
2
11-4
Symptom
Possible Cause
-
Management
module.
Backplane.
Table 11-2 Fan module troubleshooting table
Symptom
Possible Cause
The Active
Fan module
LED is off or
Fault.
solid amber.
The console
reports FAN
failure.
The Active
Fan module
LED of one
Fault.
Troubleshooting
Hitachi Compute Blade 500 Series System Service Manual
Actions / Verifications
Action 2
1
Replace the suspected power supply or
.
module.
2
Reinstall all power supplies and modules
.
in the original bay.
3
Connect all power cord to the power
.
supplies, and then power on the server
chassis.
Verification 2
1
If the Power LED lit on green, the
.
replacing is completed.
2
If the Power LED indicates other than
.
normal condition, then go to step 4.
Action 1
1
See management module troubleshooting
.
table.
2
Contact with Hitachi Data Systems
.
technical support. See the Getting help
section in this manual.
Actions / Verifications
Action 1
1
Remove the failed fan module.
.
2
Inspect visually the connector for
.
damage.
3
Reinstall it to the original bay.
.
Verification 1
1
If the Active LED lit on green, then
.
replacing is completed.
2
If the Active LED remained amber,
.
then go to the following Action 2.
Action 2
1
Remove the failed fan module and
.
replace it with the spare one.
Verification 2
1
If the Active LED lit on green, then
.
replacing is completed.
2
If the Active LED remained amber,
.
then go to step 3.
Action 1