No.
9
Notes:
1
.
2
.
3
.
4
.
Note: The Personality for Emulex 10Gb LAN mezzanine card and LOM is
fixed to NIC by default and cannot change.
9
Port Selection menu window is displayed. Select the port#0, and then
.
press Enter.
10
MultiChannel Configuration window is displayed. Set up the
.
configuration of PXE Boot Support for the replaced card corresponding
to the ones of the failed card that you recorded in the previous
procedures.
11
If PXE Boot Support is Enabled, confirm and record Bandwidth and
.
LPVID.
12
Select Save, and then press Enter.
.
7-84
Server model
# of CNA
2
The # of CNA indicates the total number of installed Emulex 10Gb CNA
mezzanine card and LAN mezzanine card.
Confirm that the indicated number of controllers in Controller Selection Menu
window is equal to the # of Controller indicated in this table for the replaced
server configuration.
The controller #0 for is assigned to LOM for CB 520H B1/B2 (GGAGC0Bn- with
LOM).
The controller #0 and #1 are assigned to LOMs for CB 540A B1 (GGAGD0Bn-
with LOM).
Configuring Emulex mezzanine card
Hitachi Compute Blade 500 Series System Service Manual
1
2
# of CTRL
6
Controller #
4
#0, #1 for LOMs
#2, #3 for Mezz #2
#4, #5 for Mezz #4