Removing a fan module
1
Put on an anti-static wrist strap.
.
2
Connect web console. See
.
section.
3
Turn on the maintenance mode from web console.
.
See
4
Pull the lock tab while unlocking it and then remove the failed fan module.
.
Installing a fan module
1
Put on an anti-static wrist strap.
.
2
Reverse the removal procedure.
.
3
Turn off the maintenance mode from web console.
.
See
4
Verify that the replacement was successful through the MAR log.
.
See
Replacing a front panel module
This procedure describes how to replace a front panel module. The front
panel module is a hot-swappable component and allows the front panel
module replacement with the server chassis power on.
Removing a front panel module
1
Put on an anti-static wrist strap.
.
2
Connect web console. See
.
section.
5-124
Maintenance mode on/off procedure on page 4-10
Figure 5-156 Removing a cooling fan module
Maintenance mode on/off procedure on page 4-10
Alert information identification procedure on page 4-5
Replacing parts
Hitachi Compute Blade 500 Series System Service Manual
Web console login procedure on page 4-3
Web console login procedure on page 4-3
section.
section.
section.