Put on an anti-static wrist strap.
.
2
Connect web console. See
.
section.
3
Turn on LID LED for identifying the target module.
.
See
4
Turn on the maintenance mode from web console.
.
See
5
Identify F/W version and take notes of it.
.
See
6
If you have the record of switch mode of failed FC switch module, skip
.
this step.
For confirming the switch mode of FC switch module, see
switch mode of FC switch module on page
7
Back up the configuration data to console PC.
.
See
8
Power the target switch module off. See
.
page 4-62
9
Remove all cables and SFP+ modules from the failed switch module.
.
See
10
Release the blue lock tab and then pull the lever, as shown below.
.
11
Holding the switch module, carefully slide out the switch module from the
.
chassis and place it on an anti-static mat.

Installing a switch module

1
Put on an anti-static wrist strap.
.
2
Reverse the removal procedure to install the switch module.
.
Identify LED (LID) on/off procedure on page 4-7
Maintenance mode on/off procedure on page 4-10
F/W version identification procedure on page 4-22
Backup/restore procedure on page 4-30
section.
Removing an SFP+ module on page 5-114
Figure 5-142 Removing the switch module
Replacing parts
Hitachi Compute Blade 500 Series System Service Manual
Web console login procedure on page 4-3
4-25.
section.
Power off the switch module on
section.
section.
section.
Confirming
section.
5-111

Hide quick links: