Hitachi CB 520H B1 Service Manual page 441

Compute blade 500 series
Hide thumbs Also See for CB 520H B1:
Table of Contents

Advertisement

Select Resources tab and select Modules > Server Blades > a target
blade that should update the FRU information.
[For SMP CB 520X B1/B2/B3]
Select Resources tab and select Modules > Server Blades > Server
Blade n of the SMP configuration > a target blade that should
update the FRU information.
2
Select Hardware tab.
.
3
Click Show FRU/Sensor.
.
4
The FRU/Sensor Information dialog box is displayed, click Edit > LOM
.
Type.
5
The Edit LOM type dialog box is displayed, select 0x02, and click
.
Confirm.
6
The Confirm dialog box is displayed, and then click OK.
.
7
After the FRU update process has completed, the FRU/Sensor
.
Information dialog box is displayed again. Confirm that LOM type field is
0x02.
Hitachi Compute Blade 500 Series System Service Manual
Change LOM configuration
10-9

Hide quick links: