Server Blade Troubleshooting Table - Hitachi CB 520H B1 Service Manual

Compute blade 500 series
Hide thumbs Also See for CB 520H B1:
Table of Contents

Advertisement

Step
3
4
5

Server blade troubleshooting table

Step
1
Symptom
Possible Cause
The Power LED
Management
is solid green
module fault
and the Error
LED is solid red.
The Primary LED is
Boot Enable
blinking in green for
configuration
a long time.
-
Management
module.
Table 11-4 Server blade troubleshooting table
Symptom
Possible Cause
A server
No power.
blade does
Loose
not power
connection.
up.
Damaged
All LEDs:
connector.
Off.
Troubleshooting
Hitachi Compute Blade 500 Series System Service Manual
Actions / Verifications
2
If the symptom still exists, then go to
.
step 5.
Action 1
1
Push the Shutdown switch about 4
.
seconds to power off the failed
management module.
2
Remove the failed management
.
module and replace it the spare one.
Verification 1
1
If the symptom no longer exists,
.
replacing is completed.
2
If the symptom still exists, then go to
.
step 5.
Action 1
1
Verify that the BOOT ENABLE
.
configuration is enable condition.
2
Wait 5 minutes, the management
.
module will be rebooting.
Verification 1
1
If the Power LED is solid green after
.
blink in green, then the repair is
completed.
2
If the symptom still exists, then go to
.
step 5.
Action 1
1
Contact with Hitachi Data Systems
.
technical support. See the Getting
help section in this manual.
Actions / Verifications
Action 1
1
Remove the suspected server blade.
.
2
Inspect the connector for damage.
.
3
Install it into the original bay again if it
.
did not have damaged connector.
Verification 1
1
If the Power LED starts blink in green and
.
Error/Fault LEDs are off, go to Action 2.
2
If the suspected server blade has
.
damaged connector, then go to step 6
3
If all LEDs are still off, then go to step 6.
.
11-7