Step
5.
Enter digital E&M voice
subscriber line view.
6.
Configure the maximum
duration of delay signal in
delay start mode.
7.
Configure the delay that the
called party must wait before
sending a delay signal after it
detects a seizure signal.
To configure the wink start mode:
Step
1.
Enter system view.
2.
Enter E1/T1 interface view.
3.
Create a TS set for digital
E&M signaling and select the
immediate start mode.
4.
Exit E1/T1 interface view.
5.
Enter digital E&M voice
subscriber line view.
6.
Configure the maximum time
the calling party waits for
wink signal after sending the
seizure signal in wink start
mode.
7.
Configure the maximum
duration of the wink signal
sent by the called party in
wink start mode.
8.
Configure the minimum
delay the called party must
wait before sending a wink
signal in wink-start mode.
Enabling E&M non-signaling mode
Analog E&M provides only one private line, which cannot meet the requirement of large-capacity
private lines. Therefore, digital E&M non-signaling should be supported by the VE1/VT1 interface.
The calling process is similar to that of analog E&M signaling except that digital signals are used
instead of analog signals. In this way, a VE1 interface can provide 30 private lines, and a VT1
interface can provide 23 private lines, thereby enlarging the system capacity.
This feature should be used with the PLAR function, you must also execute the private-line
command on the calling voice gateway. For more information about the PLAR function, see
"Configuring dial plans."
Before you enable E&M non-signaling mode, E&M signaling must operate in immediate start mode.
For more information about the analog E&M non-signaling mode, see
subscriber
line."
To enable E&M non-signaling mode:
Command
subscriber-line
slot-numbe:ts-set-number
delay hold millseconds
delay rising millseconds
Command
system-view
controller { e1 | t1 } slot-number
timeslot-set ts-set-number
timeslot-list timeslots-list signal
e&m-wink
quit
subscriber-line
slot-numbe:ts-set-number
delay wink-rising millseconds
delay wink-hold millseconds
delay send-wink millseconds
84
Remarks
N/A
Optional.
The default is 400 milliseconds.
Optional.
The default is 300 milliseconds.
Remarks
N/A
N/A
N/A
N/A
N/A
Optional.
The default is 2,000 milliseconds.
Optional.
The default is 500 milliseconds.
Optional.
The default is 200 milliseconds.
"Configuring E&M voice