Configuring R2 Digital Line Signaling - HP FlexNetwork MSR Series Configuration Manual

Hide thumbs Also See for FlexNetwork MSR Series:
Table of Contents

Advertisement

Step
5.
Set the length of called
numbers that can be
received.
For more information about the POS terminal service, see HPE FlexNetwork MSR Router Series
Comware 5 Terminal Access Configuration Guide.

Configuring R2 digital line signaling

Step
1.
Enter system view.
2.
Enter E1/T1 interface view.
3.
Create a TS set and enable
R2 signaling for it.
4.
Enter R2 CAS view.
5.
Enable the terminating side
to send answer signal.
6.
Enable the originating side to
support re-answer signal
processing.
7.
Enable the terminating side
to send clear-forward
acknowledgement signal
(clear-back signal).
8.
Enable metering for R2
signaling.
9.
Enable the terminating side
to send seizure
acknowledgement signal.
10. Configure the ABCD bit
pattern for each type of R2
line signal.
11. Configure the C and D signal
bits.
12. Configure line signal
inversion mode.
Command
posa called-length calledlength
Command
system-view
controller { e1 | t1 } slot-number
timeslot-set ts-set-number
timeslot-list timeslots-list signal
r2
cas ts-set-number
answer enable
re-answer enable
clear-forward-ack enable
force-metering enable
seizure-ack enable
dl-bits { answer | blocking |
clear-back | clear-forward | idle |
seize | seizure-ack |
release-guard } { receive |
transmit } ABCD
renew ABCD
reverse ABCD
79
Remarks
Optional.
By default, the length
of the called numbers
that can be received
is 31 digits.
Remarks
N/A
N/A
N/A
N/A
Optional.
Enabled by default.
Optional.
By default, the originating side
does not support processing of
re-answer signals.
Optional.
Disabled by default.
Optional.
Disabled by default.
Optional.
Enabled by default.
Optional.
For more information, see
11.
Optional.
N/A
Optional.
The default is 0000, that is, line
signal inversion disabled.
Table

Advertisement

Table of Contents
loading

Table of Contents