Configuring The Time Adjustment Function; Querying The Circuits Of A Timeslot Or A Range Of Timeslots; Configuring Digital Lgs Signaling; Configuration The Time Adjustment Function - HP FlexNetwork MSR Series Configuration Manual

Hide thumbs Also See for FlexNetwork MSR Series:
Table of Contents

Advertisement

Configuring the time adjustment function

Step
1.
Enter system view.
2.
Enter E1/T1 interface view.
3.
Create a TS set for digital
E&M signaling and select a
start mode.
4.
Exit E1/T1 interface view.
5.
Enter digital E&M voice
subscriber line view.
6.
Configure the maximum
interval between any two
digits of a dialed number.
7.
Configure the maximum time
the calling party waits for a
ringback response.
8.
Configure the maximum time
the called party waits for the
first digit.

Querying the circuits of a timeslot or a range of timeslots

Step
1.
Enter system view.
2.
Enter E1/T1 interface view.
3.
Create a TS set for digital
E&M signaling and select a
start mode.
4.
Enter digital E&M signaling
view.
5.
Query the circuits of a
timeslot or a range of
timeslots.

Configuring digital LGS signaling

Configuration the time adjustment function

Step
1.
Enter system view.
2.
Enter E1/T1 interface view.
Command
system-view
controller { e1 | t1 } slot-number
timeslot-set ts-set-number
timeslot-list timeslots-list signal
{ e&m-delay | e&m-immediate |
e&m-wink }
quit
subscriber-line
slot-number:ts-set-number
timer dial-interval seconds
timer ring-back seconds
timer wait-digit { seconds |
infinity }
Command
system-view
controller { e1 | t1 } slot-number
timeslot-set ts-set-number timeslot-list
timeslots-list signal { e&m-delay |
e&m-immediate | e&m-wink }
cas ts-set-number
ts query timeslots timeslots-list
Command
system-view
controller { e1 | t1 } slot-number
86
Remarks
N/A
N/A
N/A
N/A
N/A
Optional.
The default is 10 seconds.
Optional.
The default is 60 seconds.
Optional.
The default is 5 seconds.
Remarks
N/A
N/A
N/A
N/A
Optional.
Remarks
N/A
N/A

Advertisement

Table of Contents
loading

Table of Contents