Step
3.
Set a physical state change
suppression interval on the
T1 interface.
Restoring default settings for a T1 voice interface
Step
1.
Enter system view.
2.
Enter T1 interface view.
3.
Restore the default settings
on the T1 voice interface.
Configuring the voice subscriber line for a TS set
A TS set is a list of timeslots on an E1/T1 interface which abstractly forms a logical voice subscriber
line used for the configuration of R2 signaling, digital E&M signaling, digital LGS signaling and other
voice functions. For each TS set, the system automatically creates a logical voice subscriber line
numbered in the form of E1/T1 interface number:TS set number. On the voice subscriber line, you
can conveniently configure signaling and other voice functions for the corresponding E1/T1 line.
Note that on each E1/T1 interface you can create only one TS set.
The digital subscriber lines have the same functions as analog subscriber lines do. For more
information, see
For the description, shutdown, private-line, receive gain, transmit gain, echo-canceller,
nlp-on, and cng-on commands, see HPE FlexNetwork MSR Router Series Comware 5 Voice
Command Reference.
Configuration prerequisites
Complete basic parameters configuration for the VE1/VT1 interface you are working with.
Configuring basic functions for the voice subscriber line
To configure the basic functions for the voice subscriber line:
Step
1.
Enter system view.
2.
Enter E1/T1 interface view.
3.
Create a TS set and define
its signaling type.
4.
Exit E1/T1 interface view.
Command
link-delay delay-time
Command
system-view
controller t1 slot-number
default
"Configuring analog voice subscriber
Command
system-view
controller { e1 | t1 } number
timeslot-set ts-set-number
timeslot-list timeslots-list signal
{ e&m-delay | e&m-immediate |
e&m-wink | r2 | fxo-ground |
fxs-loop | fxs-ground | fxo-loop
| r2 }
quit
lines."