Configuring R2 Interregister Signaling - HP FlexNetwork MSR Series Configuration Manual

Hide thumbs Also See for FlexNetwork MSR Series:
Table of Contents

Advertisement

Step
13. Set timeout values of line
signals.
Table 11 Default values of signals in R2 digital line signaling
Signal
Answer
Blocking
Clear-back
Clear-forward
Idle
Seize
Seizure-ack
Release-guard

Configuring R2 interregister signaling

Step
1.
Enter system view.
2.
Enter E1/T1 interface view.
3.
Create a TS set and enable
R2 signaling for it.
4.
Enter R2 CAS view.
5.
Enable the terminating side
to request calling party
information.
6.
Set the range for the number
of calling number digits to be
collected.
7.
Configure the number of
digits that should be
collected to request a calling
party flag.
8.
Set the interdigit timeout
time in interregister
signaling.
Command
timer dl { answer | clear-back |
clear-forward | | re-answer |
release-guard | seize } time
Default rx-bits ABCD
0101
1101
1101
1001
1001
0001
1101
1001
Command
system-view
controller { e1 | t1 } slot-number
timeslot-set ts-set-number
timeslot-list timeslots-list signal
r2
cas ts-set-number
ani { all | ka }
ani-collected min min-value max
max-value
ani-offset number
ani-timeout timer-length
80
Remarks
Optional.
The default is 60,000 milliseconds
for answer signal; 10,000
milliseconds for clear-back signal
and clear-forward signal and
release-guard signal; 1,000
milliseconds for seizure signal
and re-answer signal.
Default tx-bits ABCD
0101
1101
1101
1001
1001
0001
1101
1001
Remarks
N/A
N/A
N/A
N/A
Optional.
Disabled by default.
Optional.
By default, no restriction is placed
on the number of calling number
digits to be collected.
Optional.