Step
10. Specify the FXO voice
subscriber line to be
exclusively used by the
bound FXS voice
subscriber line.
Configuring E&M voice subscriber line

Configuration prerequisites

The router is equipped with an applicable E&M interface card.
The basic functions of E&M voice subscriber lines are configured.

Configuring cable type

The configuration of the cable between a voice router and its peer device affects only voice
transmission and has no impact on signaling. Improper configuration can reduce the two-way
communication to a one-way voice communication.
To configure the cable type for the analog E&M trunk:
Step
1.
Enter system view.
2.
Enter voice subscriber line
view.
3.
Configure the cable type for
the E&M voice subscriber
line.

Configuring signal type

Step
1.
Enter system view.
2.
Enter voice subscriber line
view.
3.
Configure a signal type for
the E&M voice subscriber
line.

Configuring start mode

To configure the immediate start mode:
Step
1.
Enter system view.
Command
caller-permit calling-string
Command
system-view
subscriber-line line-number
em-phy-parm { 2-wire | 4-wire }
Command
system-view
subscriber-line line-number
type { 1 | 2 | 3 | 5 }
Command
system-view
43
Remarks
Optional.
By default, no calling number is
configured. That is, incoming
calls are not restricted.
Remarks...
N/A
N/A
The default is 4-wire.
Remarks
N/A
N/A
The default is 5 (corresponding V
type signal).
Remarks