Call Node Configuration Example 1: Dial Terminator Match, Normal Secondary Call - HP FlexNetwork MSR Series Configuration Manual

Hide thumbs Also See for FlexNetwork MSR Series:
Table of Contents

Advertisement

Call node configuration example 1: dial terminator match,
normal secondary call
Network requirements
As shown in
Router B to meet the following requirements.
After the subscriber originates a SIP call by dialing 300 (the IVR access number of Router B)
from Telephone A, Router B plays the audio file welcome.wav.
The subscriber dials 50# at Telephone A to originate a secondary call and then Telephone B1
rings.
If the subscriber dials a wrong number at Telephone A, Router B plays the audio file
input_error.wav.
If no number is dialed at Telephone A within the timeout time, Router B plays the audio file
timeout.wav.
Figure 91 Network diagram
Configuration procedure
1.
Configure Router A:
# Configure POTS voice entity 100.
<RouterA> system-view
[RouterA] voice-setup
[RouterA-voice] dial-program
[RouterA-voice-dial] entity 100 pots
[RouterA-voice-dial-entity100] match-template 100
[RouterA-voice-dial-entity100] line 1/0
[RouterA-voice-dial-entity100] quit
# Configure VoIP voice entity 300 to Router B.
[RouterA-voice-dial] entity 300 voip
[RouterA-voice-dial-entity300] match-template 300
[RouterA-voice-dial-entity300] address sip ip 1.1.1.2
[RouterA-voice-dial-entity300] outband sip
2.
Configure Router B:
# Configure POTS voice entity 500 and POTS voice entity 50.
<RouterB> system-view
[RouterB] voice-setup
Figure
91, configure an IVR access number and customize Call node functions on
293

Advertisement