Configuring Packet Loss Compensation Mode; Setting The Electrical Impedance - HP FlexNetwork MSR Series Configuration Manual

Hide thumbs Also See for FlexNetwork MSR Series:
Table of Contents

Advertisement

Step
2.
Enter FXS voice
subscriber line view.
3.
Enable CID on the FXS
voice subscriber line.
4.
Enable the FXS voice
subscriber line to send
calling identity
information to the remote
end.
5.
Configure the calling
name for the FXS voice
subscriber line.
6.
Configure the format of
messages (which carry
the calling number
information) transmitted
over the FXS voice
subscriber line.
7.
Configure the standard
for the FXS voice
subscriber line to send
messages carrying the
calling number
information.

Configuring packet loss compensation mode

Step
1.
Enter system view.
2.
Enter FXS voice subscriber
line view.
3.
Configure the packet loss
compensation mode for the
FXS voice subscriber line.

Setting the electrical impedance

Step
1.
Enter system view.
2.
Enter FXS voice subscriber
line view.
3.
Set the electrical impedance.
Command
subscriber-line line-number
cid display
cid send
calling-name text
cid type { complex | simple }
cid standard-type { bellcore |
brazil }
Command
System-view
subscriber-line line-number
plc-mode { general | specific }
Command
system-view
subscriber-line line-number
impedance { country-name | r550
| r600 | r650 | r700 | r750 | r800 |
r850 | r900 | r950 }
36
Remarks
N/A
Optional.
Enabled by default.
Optional.
Enabled by default.
Optional.
Not configured by default.
Optional.
The default is complex.
When the peer end supports only one
message format, you must use the
same message format at the local end
as the one used at the peer end.
Optional.
By default, bellcore is adopted.
Remarks
N/A
N/A
Optional.
By default, the specific algorithm
provided by the voice gateway is
configured for the FXS voice
subscriber line.
Remarks
N/A
N/A
Optional.
By default, the electrical
impedance is the impedance
value applicable to China.