Configuring Rspan - Huawei Quidway S3100 Series Operation Manual

Table of Contents

Advertisement

Operation Manual – QoS
Quidway S3100 Series Ethernet Switches
mirroring-group 1:
type: local
status: active
mirroring port:
monitor port: Ethernet1/0/1

1.9 Configuring RSPAN

Remote switched port analyzer (RSPAN) breaks through the limitation that the
monitored port and the monitoring port have to be on the same switch. It permits the
monitored port and the monitoring port to be located across multiple devices in the
network, thus enables easy management on remote switches.
RSPAN application is shown in Figure 1-4.
Source
Source
Switch
Switch
Source Port
Source Port
Figure 1-4 RSPAN application
The following three types of switches implements the RSPAN function:
Source switch: The switch where the monitored port is located
Intermediate switch: A switch that is located between the source and destination
switches in the network
Destination switch: The switch where the remote destination monitoring port is
located
Ports on these switches that are involved in monitoring are described in Table 1-16.
Ethernet1/0/2
both
Reflector port
Reflector port
Huawei Technologies Proprietary
Remote-probe VLAN
Remote-probe VLAN
Intermediate Switch
Intermediate Switch
Trunk port
Trunk port
1-14
Chapter 1 QoS Configuration
Destination
Destination
Switch
Switch
Destination port
Destination port

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents