Operation Manual – Login
Quidway S3100 Series Ethernet Switches
(1)
(1)
(1) RS-232 port
Figure 5-1 Connect to the Console port
Launch a terminal emulation utility (such as Terminal in Windows 3.X or
HyperTerminal in Windows 9X) on the PC, with the baud rate set to 9,600 bps,
data bits set to 8, parity check set to off, and flow control set to off.
Turn on the switch. When the switch is starting, the information about self-testing
appears on the terminal window. When you press Enter after the self-testing
finishes, the prompt (such as <Quidway>) appears, as shown in the following
figure.
Figure 5-2 The terminal window
Execute the following commands in the terminal window to assign an IP address
to the management VLAN interface of the switch.
<Quidway> system-view
# Enter management VLAN interface view.
[Quidway] interface vlan-interface 1
# Remove the existing IP address of the management VLAN interface.
[Quidway-Vlan-interface1] undo ip address
(3)
(3)
(2) Console port
Huawei Technologies Proprietary
Chapter 5 Logging in through Web-based Network
(2)
(2)
5-2
Management System
(3) Configuration cable