Advanced 802.1X Configuration - Huawei Quidway S3100 Series Operation Manual

Table of Contents

Advertisement

Operation Manual – 802.1x
Quidway S3100 Series Ethernet Switches
Operation
Configure
maximum
times
request packets
Configure
timers
Trigger
quiet-period timer
Note:
As for the dot1x max-user command, if you execute it in system view without
specifying the interface-list argument, the command applies to all ports. You can
also use this command in port view. In this case, this command applies to the
current port only and the interface-list argument is not needed.
As for the configuration of 802.1x timers, the default values are recommended.

1.5 Advanced 802.1x Configuration

Advanced 802.1x configurations, as listed below, are all optional.
CAMS cooperation configuration, including multiple network adapters detecting,
proxy detecting, and so on
Client version checking configuration
Static IP address checking configuration
Guest VLAN configuration
Command
the
retry
dot1x retry max-retry-value
to
send
dot1x
{
handshake-period
handshake-period-value
quiet-period
802.1x
quiet-period-value
tx-period tx-period-value |
supp-timeout
supp-timeout-value
server-timeout
server-timeout-value }
the
dot1x quiet-period
Huawei Technologies Proprietary
Optional
By default, the maximum retry
times to send a request
packet is 2. That is, the
authenticator system sends a
request packet to a supplicant
system for up to two times by
default.
Optional
The default values of 802.1x
timer
timers are as follows:
|
|
|
Optional
By default, a quiet-period
timer is disabled.
1-16
Chapter 1 802.1x Configuration
Description
handshake-period-value:
15 seconds
quiet-period-value:
seconds
tx-period-value:
seconds
supp-timeout-value:
seconds
server-timeout-value: 100
seconds
60
30
30