Symptom List:
FRONT AND REAR BLOWER OUTPUT 1 OPEN
FRONT AND REAR BLOWER OUTPUT 2 OPEN
Test Note: All symptoms listed above are diagnosed using the same tests.
The title for the tests will be FRONT AND REAR BLOWER
OUTPUT 1 OPEN.
When Monitored and Set Condition:
FRONT AND REAR BLOWER OUTPUT 1 OPEN
When Monitored: Continuously.
Set Condition: If the FCM detects no voltage present on the Front/Rear Blower Motor
Relay Control circuit.
FRONT AND REAR BLOWER OUTPUT 2 OPEN
When Monitored: Continuously.
Set Condition: If the FCM detects no voltage present on the Front/Rear Blower Motor
Relay Control circuit.
FRONT & REAR BLOWER OUTPUT 1/2 OPEN
TEST
1
View repair.
Repair
AUTOMATIC TEMPERATURE CONTROL
POSSIBLE CAUSES
ACTION
Refer to symptom Front and Rear Blower Output 1 Open or
symptom Front and Rear Blower Output 2 Open in the Heating &
A/C category.
Perform BODY VERIFICATION TEST - VER 1.
219
APPLICABILITY
All