Symptom:

INCOMPLETE POWER CLOSE - OVER CURRENT

When Monitored and Set Condition:
INCOMPLETE POWER CLOSE - OVER CURRENT
When Monitored: Anytime the liftgate is in a closing operation.
Set Condition: The drive motor stall current of over 24 amps has been detected for over
500 ms. or during the initial gear engagement the drive transistor is shorted, during a
power close operation.
DTC PRESENT
BINDING LIFTGATE
GROUND CIRCUIT OPEN
LIFTGATE CLOSE DRIVER CIRCUIT SHORT TO GROUND
LIFTGATE LATCH RELEASE DRIVER CIRCUIT SHORT TO GROUND
LIFTGATE LATCH RELEASE DRIVER CIRCUIT SHORT TO HARNESS GROUND
LIFTGATE GEAR ENGAGE DRIVER CIRCUIT SHORT TO GROUND
LIFTGATE GEAR ENGAGE DRIVER CIRCUIT SHORT TO HARNESS GROUND
LIFTGATE MODULE
POWER LIFTGATE MOTOR
TEST
1
With the DRBIII , record and erase DTC's.
Turn the ignition off, wait 10 seconds, then turn the ignition on.
Operate the power liftgate several times (if possible).
With the DRBIII , read DTCs.
Does the DRBIII display INCOMPLETE POWER CLOSE- OVERCURRENT?
Yes → Go To 2
→ Using the wiring diagram/schematic as a guide, inspect the
No
POSSIBLE CAUSES
ACTION
wiring and connectors for an intermittent condition. Operate the
liftgate several times and check for any binding conditions.
Perform BODY VERIFICATION TEST - VER 1.