Ambient Temperature Sensor Circuit Short To Ground - Chrysler Town and Country 2003 Owner's Manual

Table of Contents

Advertisement

POWER DOORS - SLIDING
Symptom:

AMBIENT TEMPERATURE SENSOR CIRCUIT SHORT TO GROUND

When Monitored and Set Condition:
AMBIENT TEMPERATURE SENSOR CIRCUIT SHORT TO GROUND
When Monitored: Anytime the Power Sliding Door Module is awake.
Set Condition: If the Power Sliding Door Modules internal thermistor is shorted, this
code will set.
DTC PRESENT
POWER SLIDING DOOR MODULE
TEST
1
With the DRBIII , record and erase DTC's.
Turn the ignition off, wait 10 seconds, then turn the ignition on.
Operate the power sliding door several times from stop to stop if possible.
With the DRBIII , read ACTIVE DTCs.
Does the DRBIII display AMBIENT TEMPERATURE SENSOR CIRCUIT LOW?
Yes → Replace the Power Sliding Door Module.
→ No problem found at this time.
No
POSSIBLE CAUSES
ACTION
Perform BODY VERIFICATION TEST - VER 1.
Perform BODY VERIFICATION TEST - VER 1.
862
APPLICABILITY
All

Advertisement

Table of Contents
loading

This manual is also suitable for:

Voyager 2003Caravan 2003

Table of Contents