Power Doors - Liftgate; Ambient Temperature Sensor Circuit Open - Chrysler Town and Country 2003 Owner's Manual

Table of Contents

Advertisement

POWER DOORS - LIFTGATE

Symptom:

AMBIENT TEMPERATURE SENSOR CIRCUIT OPEN

When Monitored and Set Condition:
AMBIENT TEMPERATURE SENSOR CIRCUIT OPEN
When Monitored: Whenever the Power Liftgate Module is awake.
Set Condition: If the module senses a resistance above 382K ohms on the Liftgate
Temperature Sensor Signal circuit, this code will set. The normal range for the sensor is
1.2K to 382K ohms. At room temperature (68° F) the resistance will be between 11.2 K and
13.5K ohms.
DTC PRESENT
POWER LIFTGATE MODULE - TEMPERATURE SENSE OPEN
LIFTGATE TEMPERATURE SENSOR SIGNAL WIRE OPEN
GROUND WIRE OPEN
LIFTGATE TEMPERATURE SENSOR
TEST
1
With the DRBIII , record and erase DTC's.
Turn the ignition off, wait 10 seconds, then turn the ignition on.
Operate the liftgate several times.
With the DRBIII , read DTCs.
Does the DRBIII display AMBIENT TEMPERATURE SENSOR CIRCUIT OPEN?
Yes → Go To 2
→ Using the wiring diagram/schematic as a guide, inspect the
No
2
Remove the power liftgate motor trim panel.
Disconnect the Power Liftgate Module C2 connector.
Measure the resistance of the liftgate Temperature Sensor Signal circuit to the
Ground circuit (cavity 20) in the PLG C2 connector.
Is the resistance between 1.2k and 382K ohms?
Yes → Replace the Power Liftgate Module.
→ Go To 3
No
POSSIBLE CAUSES
ACTION
wiring and connectors for an intermittent condition.
Perform BODY VERIFICATION TEST - VER 1.
Perform BODY VERIFICATION TEST - VER 1.
798
APPLICABILITY
All
All