Incomplete Power Open - Overcurrent - Chrysler Town and Country 2003 Owner's Manual

Table of Contents

Advertisement

Symptom:

INCOMPLETE POWER OPEN - OVERCURRENT

When Monitored and Set Condition:
INCOMPLETE POWER OPEN - OVERCURRENT
When Monitored: Anytime the Power Sliding Door is in a power open operation.
Set Condition: The drive motor stall current of over 16 amps has been detected for over
500 ms. during an open operation.
DTC PRESENT
BINDING DOOR
GROUND CIRCUIT OPEN
SLIDING DOOR OPEN DRIVER CIRCUIT SHORT TO GROUND
CINCH/RELEASE MOTOR LATCH DRIVER CIRCUIT OPEN
CINCH/RELEASE MOTOR LATCH DRIVER CIRCUIT SHORT TO GROUND
DOOR MOTOR CLUTCH DRIVER CIRCUIT SHORT TO GROUND
POWER SLIDING DOOR MOTOR/CLUTCH
TEST
1
With the DRBIII , record and erase DTC's.
Turn the ignition off, wait 10 seconds, then turn the ignition on.
Operate the power sliding door several times if possible.
With the DRBIII , read DTCs.
Does the DRBIII display INCOMPLETE POWER OPEN - OVERCURRENT?
Yes → Go To 2
→ Using the wiring diagram/schematic as a guide, inspect the
No
2
Examine the door for proper fit and alignment, loose/ hard or torn seals, worn teeth
on the rack and gear (lower drive unit) or anything that would cause an obstruction
to proper operation.
Manually operate the sliding door of a known good vehicle and notice the effort
needed.
Compare the effort needed on the disabled vehicle.
Does it take more effort to operate the door than it should?
Yes → Refer to Service information for the related symptom(s).
→ Go To 3
No
POSSIBLE CAUSES
ACTION
wiring and connectors for an intermittent condition. Operate the
door several times and check for any binding conditions.
Perform BODY VERIFICATION TEST - VER 1.
Perform BODY VERIFICATION TEST - VER 1.
POWER DOORS - SLIDING
905
APPLICABILITY
All
All